Cooling Method: Water Cooling/Air Cooled
Frequency: 50Hz 1500rpm / 60Hz 1800rpm
Generator Type: Open Type, Silent Type
Starting Control Mode: Electric Starting
Price: Factory Price
Origin: China
In addition to core advantages such as power, quietness, and home backup, the value of the 6KW diesel generator is also deeply reflected in its "soft power" such as environmental standards, intelligent control, supply chain resilience, and multi scenario adaptability.
Features & Benefits
Quiet Power for Work and Home Through precise power and noise balance design, the 6KW diesel generator ensures low fuel consumption and maintenance costs in both professional and domestic scenarios, leaving professional work and family life worry-free. |
Reliable YD192FE Engine Ensuring thermal stability during long-term operation in a sealed environment and low stress output to the silent structure, the robust engineering of the 7KW diesel generator thereby significantly extends the overall lifespan of the machine, ensuring reliable performance for years to come. |
Extended Runtime for All-Night Peace of Mind The extra-large 16L fuel tank provides up to 7 hours of continuous runtime at full load, allowing you to run your essentials all night long without refueling. Paired with a 100% copper alternator and AVR, the 7KW diesel generator delivers clean, stable power. |
Technical Specifications
| TYPE | DG10000SE 6KW 7KW Air Cooled Diesel Generator | ||
| GENERATOR SET | Frequency(HZ) | 50 | 60 |
| Max Power(kW) | 6.5 | 7 | |
| Rate Power(kW) | 6 | 6.5 | |
| Rate AC Voltage(V) | 120、220、230、240、380、400 | ||
| DC Output(V/A) | 12/8.3 | ||
| Phase | Single/Three | ||
| Altermator Type | Self-excited with AVR | ||
| Starting System | Electric | ||
| Noise Level at 7m(dBA) | 72-74 | ||
| Fuel Tank Capacity(L) | 16 | ||
| Running Time(h) | 7 | ||
| ENGINE | Engine Model | YD192FE | |
| Engine Type | Single-cylinder、Vertical、Air-cooled、4-stroke Diesel Engine | ||
| Combustion System | Direct | ||
| Displacement(mL) | 499 | ||
| Engine Power(kW) | 8.2 | 9 | |
| Fuel Type | |||
| Lub Oil Capacity(L) | 1.65 | ||
| DIMENSION | Packing Size(mm) | 980*560*760 | |
| Gross Weight(kg) | 180 | ||
| 20FT | 72 | ||
| 40FT | 144 | ||
Proven Performance in Real-World Applications

Full Home Backup
Go beyond the basics. The 6KW diesel generator can handle your home's essentials (lights, fridge) plus heavier loads like a well pump or a small air conditioner, ensuring comfort and normalcy during extended power outages.

Small Business/Office Power
Keep your business online. Reliably power multiple computers, servers, lights, and POS systems to prevent costly downtime during an outage with the 7KW diesel generator.

Job Site Power
A quiet and reliable power source for your job site, capable of running multiple power tools, compressors, or a site office. The 6kw air cooled diesel generator is the ideal solution for this demanding role, providing the robust, stable power needed to maintain productivity while its quiet operation minimizes on-site disturbance.
Tailored Solutions, Customization & Packaging
Build Your Unique Product
Our full OEM/ODM service allows you to create a 6kw diesel generator that is uniquely yours. We are your partner for every detail:
Bullet Points:
● Custom Color: Match your brand's exact Pantone color scheme.
● Product Styling: We can modify the canopy design, shape, and appearance to create a distinctive look for your market.
● Control Panel: Design a completely custom panel layout with your brand, language, and required meters or digital readouts.
● Technical Specs: Configure the precise voltage (e.g., 110V/220V), frequency (50/60Hz), and socket types for any country.
Secure & Branded Packaging
Each 7kw diesel generator is packed in a heavy-duty 5-layer corrugated carton (Gross Weight: 180kg / Size: 980*560*760mm) to ensure safe arrival. We also offer customized packaging solutions, including full-color printed boxes with your branding or durable wooden crates for specific needs. A 40HQ container loads 144 units, maximizing your shipping efficiency.


FAQs
Q1: What is the minimum order quantity (MOQ)?
A1: Our standard MOQ is 10 units air cooled diesel generator. For fully customized OEM orders for new panels, styling, or colors, a higher MOQ may apply. Please contact our specialists to discuss your project.
Q2: What are the key differences between an open-frame and a silent (canopy) 6 diesel generator?
A2: The core differences lie in noise level, application suitability, and design:
1.Open-Frame Generator: Features an exposed, heavy-duty steel frame. It offers maximum cooling, easy access for maintenance, and is generally more cost-effective. However, it is significantly louder, with operational noise levels often around 80-85 dBA at 7 meters. It is best suited for industrial sites, farms, or remote construction areas where noise is not a primary concern.
2.Silent/Canopy Generator: Enclosed in a professional-grade acoustic canopy lined with sound-absorbing foam and baffles. This design drastically reduces noise to approximately 72-75 dBA at 7 meters (comparable to a normal conversation). It is the ideal choice for residential backup, noise-sensitive job sites (e.g., in urban areas), outdoor events, hospitals, schools, and any application where minimizing disturbance is crucial. The silent version prioritizes quiet operation without sacrificing the generator's robust power output.
Q3: What is the warranty period?
A3: We offer a comprehensive 1-year or 1000 running hours warranty (whichever comes first) covering all manufacturing defects.
Q4: What are the main maintenance requirements?
A4: The primary maintenance involves regularly checking and changing the engine oil (1.65L capacity) and cleaning the air filter. A detailed schedule is in the user manual.
Q5: How long can an 7kw diesel generator run continuously, and what affects its runtime?
A5: The continuous runtime of an 7KW diesel generator is primarily determined by its fuel tank capacity and the electrical load applied. A typical model with a 20-25 liter fuel tank can run for approximately 8 to 10 hours at 50-75% of its rated load. Running at a lighter load will extend this time, while operating at or near full capacity will shorten it. For applications requiring longer unattended operation (e.g., overnight or multi-day backup), the generator can be connected to a larger external fuel tank. It's important to note that most 7KW air cooled diesel generators are designed for standby use and may require scheduled cooldown periods if run continuously for more than 12-24 hours, as per the manufacturer's guidelines.